To Ensure the Chemical properties of Metal as per Alloy standard, We always follow the standard practice of testing the Metal before go to the production by the use of Spectrometer.
This machine is used for removing hydrogen and other non metallic inclusions from molten aluminum.
After degassing process it is necessary to ensure that molten metal is free from Hydrogen Gas and other impurities,So with the help of Density Indexer we take the sample from molten metal and check the data with standard Density Index.
UTS machine is use to test the tensile strength and compressive strength of materials. Capacity Upto 30KN.